AIR FLOW DYNAMICS & DUCT SIZING REFERENCE GUIDE

AIR FLOW DYNAMICS & DUCT SIZING REFERENCE GUIDE SUPPLY OR RETURN DUCT SIZE/CAPACITY (.09 to .10 pressure drop per 100 EL) CFM Round (No. SL) Rectangular (TD) 50 5 8 x 6 75 5 8 x 6 100 6 8 x 6 3½ x 10 (110) 125 6 8 x 6 3½ x 12 (140) 150 7 8 x 6 3½ x 14 (160) 175 7 8 x 6 AIR FLOW DYNAMICS & DUCT SIZING REFERENCE GUIDEAIR FLOW DYNAMICS & DUCT SIZING REFERENCE GUIDE SUPPLY OR RETURN DUCT SIZE/CAPACITY (.09 to .10 pressure drop per 100 EL) CFM Round (No. SL) Rectangular (TD) 50 5 8 x 6 75 5 8 x 6 100 6 8 x 6 3½ x 10 (110) 125 6 8 x 6 3½ x 12 (140) 150 7 8 x 6 3½ x 14 (160) 175 7 8 x 6

Aerofoil Manufacturer, For Flow Measurement, Flow

The difference between these gives input for flow rate calculation. For designing of aerofoil, for rectangular duct, the dimensions are transformed into a similar circular section and performed the sizing. The results are re-transformed back to rectangular dimensions. Size limits:500 x 500 mm minimum Beta Ratio:0.2 to 0.8 Air Ducts - Sizing - Engineering ToolBoxDuct Velocity - Calculate velocities in circular and rectangular ducts - imperial and SI-units - online calculator; Ducts Sizing - Velocity Reduction Method - The velocity reduction method can be used for sizing air ducts ; Maximum Size of Duct - or Pipe - through Steel Joists - K series joists and maximum size of ducts and pipes Air Flow Meters & Gas Flow Meters Intek, Inc.Duct & pipe gases Pipe Sizes 1 and larger pipes:Wetted Surface:316 SS:Hastelloy C-276 ®; Monel ® Flow Velocity Limits:25-25,000 SFPM (0.127-127 meter/sec.) Consult Factory:Turndown Ratio:10:1:Up to 200:1:Accuracy +/- 1% of reading Repeatability +/- 0.5%:Max. Temperature:175 ºF (80 ºC) Up to 500 ºF (260 ºC) Max. Pressure:Depends on Fitting

Air Flow Meters & Gas Flow Meters Intek, Inc.

We offer air and gas flow meters for pipes and ducts from three inches to several feet in diameter. The flow measurement is reliable with no moving parts construction. All Sierra Flow Products - Flow Controllers & Mass Flow MetersTube, Pipe, Duct Size (3) 1.0 to 12 inch (25 to 304mm) 1/8 to 3/4 inch (3 to 19mm) Up to 72" (2M) and Larger Differentiators (7) Multi-Gas:One Device Low Pressure Drop High Pressure Flow High Temperature Flow Duct Sizing Chart - Hamilton Home ProductsIn order to maintain velocity, reduce duct size. Never locate ducts at the end of the trunk line run. Last take-off run to be located 12" - 18" from end. Always stagger take-off ducts by 12" to maintain pressure. Use insulated duct or duct board in unheated spaces. Flexible duct work must be stretched tightly for maximum air flow.

Ductwork sizing, calculation and design for efficiency

Jul 03, 2018 · A round duct with a cross sectional area of 0.6m2 has a perimeter of 2.75m. A rectangular duct with an equal cross sectional area has a perimeter of 3.87m. The rectangular duct therefore requires more metal for its construction, this adds more weight and costs to the design. FLOW STRAIGHTENER FOR VORTEX FLOW METERSVortex Flow Meters. The size of the straightener should always match the meter size (as opposed to the original pipe size). The flow straightener is made of 304/A 351 CF8 Stainless Steel. SIZE DIM A DIM B DIM C DIM D NUMBER OF HOLES 2 3.93 1.0625 .28 2.14 35 3 5.31 1.0625 .43 3.24 35 Flow Meters Huge Savings On All Orders! - PVC Pipe Flow meter rate working range is directly related to pipe size and diameter. Flow rate accuracy ranges from +/- 1% up to +/- 5%. The Blue White® F-1000, F-2000 and Micro Flo meters are our most precise with a programmable digital read out up to four (4) decimal places and with flow rate totalizer.

Flow Meters Huge Savings On All Orders! - PVC Pipe Supplies

Available pipe flow meters are made from acrylic, polysulfone or PVDF material types. Flow meter costs range from $85 up to $1548. Flow meters are available for installation on pipe sizes from 1/4 up to 12. They can be mounted in line, saddle mounted, or panel mounted. We offer Blue White flow meters in mechanical or digital types. Flow Meters by Pipe Size - 1/8 to 3/4 inch Sierra Tube, Pipe, Duct Size (1) 1/8 to 3/4 inch (3 to 19mm) Fluid (1) Gas; Flow Range (3) 0 to 100 sccm or less; 0 to 50 slpm or less; 0 to 1000 slpm or less; Type & Technology (4) Mass Flow Controllers / Meters Mass Flow Meters (All) MEMS Technology Scientific Series (3) Flow Rate Calculator - calculate the flow rate of a pipeFree online Flow Rate calculator which helps you calculate the flow rate of any pipe given its diameter and liquid/gas velocity or its height and width (for a rectangular pipe) and velocity. The pipe flow rate calculator (a.k.a. discharge rate calculator) accepts input in both metric and imperial units:m/s, km/h, ft/s, yd/s, mph, and outputs in both metric units and imperial ones:cu ft, cu

Flowmeter piping requirements Flow Control Network

The size and orientation of the impulse-line pressure taps depend on both the pipe size and the process fluid. avoid a buildup or accumulation of any secondary phase (solids or air). Any entrained air should be carried out of the meter by flow, or by buoyancy (at zero flow). The straight length of pipe for the vortex meter must be the Flowmeter piping requirements Flow Control NetworkThe straight length of pipe for the vortex meter must be the same size as the meter and its length should be about the same as required for an orifice installation with a beta ratio of 0.7. Most vortex flowmeter manufacturers recommend a minimum length of 30 pipe diameters downstream of control valves, and three-to-four pipe diameters between the meter and downstream pressure taps. Friction Loss Calculator - Good Calculatorsh L = 10.67 * L * Q 1.852 / C 1.852 / d 4.87 (SI Units) In this equation, hL represents friction head loss (meters of H2O), L represents length of pipe (meters), d represents internal pipe diameter (meters), Q represents flow rate through the pipe (cubic meters per second), and C represents the Hazen-Williams coefficient, which will vary according to how smooth the internal surfaces of the pipe are.

How Much Water Can Flow Through A Pipe (GPM/GPH)?

Water Flow (GPM/GPH) based on Pipe Size and Inside/Outside Diameters :Assume Gravity to Low Pressure. About 6 f/s flow velocity, also suction side of pump:Assume Average Pressure (20-100PSI). About 12 f/s flow velocity:Assume "High Pressure" PEAK flow. About 18 f/s flow velocity :Pipe Size In what pipe sizes can the thermal mass flow meter measure?Nov 05, 2014 · The Sage Metering thermal mass flow meters can accurately measure in pipe sizes as small as ¼ in (6.35 mm) and as large as 36 in (914.4 mm). However, when measuring exhaust gases in ducts the end user should consult with the factory first. Additionally, if you have an application for pipe sizes outside the ¼ inch to 36 inch range, consult with our factory first before ruling out using a In what pipe sizes can the thermal mass flow meter measure?Nov 05, 2014 · The Sage Metering thermal mass flow meters can accurately measure in pipe sizes as small as ¼ in (6.35 mm) and as large as 36 in (914.4 mm). However, when measuring exhaust gases in ducts the end user should consult with the factory first. Additionally, if you have an application for pipe sizes outside the ¼ inch to 36 inch range, consult with our factory first before ruling out using a

NEW DUCT SIZING CHART - HVACDirect

Design CFM 4" CFM 6" CFM 8" CFM 10" CFM 12" 60 6x4 60 4x6 90 4x8 120 4x10 150 4x12 90 8x4 110 6x6 160 6x8 215 6x10 270 6x12 120 10x4 160 8x6 230 8x8 310 8x10 400 8x12 150 12x4 215 10x6 310 10x8 430 10x10 550 10x12 180 14x4 270 12x6 400 12x8 550 12x10 680 12x12 210 16x4 320 14x6 490 14x8 670 14x10 800 14x12 240 18x4 375 16x6 580 16x8 800 16x10 950 16x12 270 20x4 430 18x6 PIPE SIZING CHART Natural Gas :Pipe Sizing ChartPipe length must include additional length for all fittings. Add approximately 5 feet of pipe per fitting. Natural Gas Example:A machine with a burner that requires 440,000 BTU would need a 1 -1/4 pipe for a 20 long run. NOTE:The sizing charts above list the specific pipe sizes required for the amount of BTUs for a new gas line Pipe Flow Measurement - Venturi Flowmeters - Bernoulli's In addition, each of the devices can only be used within specified limits of pipe size and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of nozzles and Venturi nozzles in pipe sizes less than 50 mm or more than 630 mm, or for pipe

Pipe diameter and flow rate calculator, online

With pipe diameter calculator pipe internal diameter is calculated using the simple relation between flow rate, velocity and cross-section area (Q=v·A). To calculate internal pipe diameter, you should only enter flow rate and velocity in corresponding fields in the calculator and click calculate button to get results. Relationship between flow rate, flow speed, and pipe With the below formula, we can understand the relationship between flow rate, flow velocity, and pipe diameter. Flow rate = Pipe cross-sectional area X Flow speed. Pipe cross-sectional area could be obtained by the following formula. Pipe cross-sectional area ID² / 4 X (ID stands for pipe inner diameter, stands for Pi which is 3.14) Residential Duct Sizing Guide - Virginia AirRectangular and Round Duct Air Volume CFM Duct Height Inches Equivalent Round Duct Air Volume 4 6 8 10 12 CFM 50 6 x 4 5 50 75 6 x 4 6 75 100 8 x 4 6 x 6 6 100 125 10 x 4 6 x 6 7 125 150 10 x 4 8 x 6 7 150 175 12 x 4 8 x 6 8 175 200 14 x 4 8 x 6 8 200 225 16 x 4 10 x 6 8 220 250 16 x 4 10 x 6 9 250 275 12 x 6 8 x 8 9 275 300 12 x 6 8 x 8 9 300

Tech Tips:Duct Sizing Chart - Coburn S

Jul 01, 2015 · For instance a 2.5 ton system (Approximately 400 CFM per ton) would require (2) 14 flexible return ducts or (1) very short flexible 18 duct to move the 1000 CFM required by the 2.5 ton system. As systems increase in efficiency, the tolerances Thermal Flowmeters for Compressed Air - Flowmeters This guide is for use with 2" (50 mm) and 2-1/2" (63 mm) CDI-5400 and 6400 flow meters. It includes a 3/16" drill bit, a 5/16" hex wrench, and an aluminum drill guide and is a cheaper option than the universal guide if you're only working with these specific pipe sizes. Volumetric Flow Rate & Rectangular Duct Width x Height to Volumetric Flow Rate Measured. Enter the volumetric amount of substance that will flow pass in a unit of time. Width. Enter the internal width of the section of duct being used to measure flow. Height. Enter the internal height of the section of duct being used to measure flow. Flow Velocity Calculation. This is the speed at which the substance

Water Flowmeters McMaster-Carr

Choose from our selection of flowmeters for water, easy-read flowmeters for water, flowmeter/totalizers for water, and more. In stock and ready to ship. What Happens to Air Flow in Ducts When Size Changes i think if i run a 4" round pipe across a 12 inch duct, through the center it will have little effect on air flow. it is a 12 x 20 duct and would pass through the duct in the center. no take offs are within 5' Flow Meters by Pipe or Duct Size - Up to 72 In. Sierra Tube, Pipe, Duct Size (2) Up to 72" (2M) and Larger; 1.0 to 12 inch (25 to 304mm) Type & Technology (7) Vortex Thermal Mass Ultrasonic Flow & Level Switches iSeries Next Generation Flow Conditioners Mass Flow Meters (All) Fluid (3) Gas; Steam